RAMSET “INTELLIGATE” CONTROL BOARD
Introduction:
Ramset’s “Intelligate” Control Board works
with Sliding, Swinging and Overhead vehicular
gate operators. It is controlled by a program-
mable microprocessor that reads and precisely
executes all functions of the Control Board.
The Control Board is powered by a separate
mounted 24 VAC transformer. This allows no
necessary board modifications between 110
VAC and 220 VAC single-phase applications.
Some of the functions of the Control Board
are: 0 - 60 seconds automatic close timer, self
adjusting E.R.D. with low and high setting,
constant warning, prewarning, secure close,
one pass, open & close delay, left/right hand
operation, plug-in loop detectors and RS485
three wire master/slave connection.
Figure 15
plug-in
Power Transformer
40VA.
Dipswitches
Automatic Timer, Prewarn,
Constant Warning, Secure Close,
Full Reverse ERD, Radio Cycle,
One Pass, Low / High ERD,
Adjustment, Close Delay,
Open Delay and Left / Right.
Relay Connections
Indicator lights, alarms and sirens.
Reverse Loop
Exit Loop
Phantom Loop
Microprocessor
Reprogrammable, controls
all functions of the operator.
ERD
Self adjusting, with low
and high adjustments.
3 Button Station
Open - Stop - Close
Foot Pedal Plug
Stops the motor from running
while the foot pedal is engaged.
Master / Slave Plug
Synchronizes movement between two
gates. 3 wires (A-, B- and Common).
Standard Connections
Reverse Loop, Fire Box, Exit Loop,
Phantom Loop, Radio, Edge Sensor,
24 VAC and Magnetic Lock.